True

Product Image

Multi-Use Dry Ice Temperature Logger with One External Sensor MP-OE-N-8-L

167.52 USD 167.52 USD 167.52 USD

586.00 AED

Multi-Use Dry Ice Temperature Logger with One External Sensor MP-OE-N-8-L

Escort iMiniplus Dry Ice Temperature Logger MP-OE-N-8-L
This is a Multi-use type of data logger.
It has one external sensor for inserting into the box containing dry ice.
It can measure from -100 to +40 °C. (-148°F to 104°F).
It can record a maximum of 8048 Readings in its internal memory.
The external sensor is a stainless steel temperature probe with 1 meter Teflon cable.

Days
Hours
Mins
Secs
1

VSKU: 1000000016

167.52 USD 167.52 USD 167.52 USD

586.00 AED

    This combination does not exist.


    Add to Cart Buy Now

    Category:

  • Data Logger


  • Multi-Use Dry Ice Temperature Logger with One External Sensor MP-OE-N-8-L


    A dry ice temperature data logger is for recording the temperature inside a box filled up with dry ice during its transportation. Dry ice is solidified Carbon Dioxide (CO2). The temperature of dry ice is around -78.5°C. It will retain its solid form from 12 to 24 hours based on the surrounding environment. Dry ice is useful in the transportation of food, medicines, vaccines, medical samples etc. at low temperatures. In these cases, you fill a thermally insulated box with dry ice and keep the items inside this box. If you want to record the temperature of such items during transportation, you may use a dry ice temperature data logger. The dry ice data logger has an external sensor. You have to insert this sensor into the box and keep the display device outside the box. You can see the current temperature, maximum and minimum temperature etc. on the screen.

    Specifications of Cryopak iMiniplus Multiple-use dry ice temperature recorder

    1. Cryopak iMiniplus Multiple-use dry ice data logger is suitable for recording the temperature during storage and transportation of Medical samples, diagnostic specimens, organs, human and animal tissues, serums, enzymes, vaccines etc.

    2. This multi-use dry ice data logger has a large LCD Display for viewing multiple data.

    3. The product Code for this multi-use dry ice data logger is MP-OE-N-8-L.

    4. The storage capacity is 8048 Readings.

    5. The sampling Interval or frequency of recording is programmable from 5 seconds-18 hours.

    6. Time Accuracy is +/-1 minutes per month.

    7. The temperature sensor is an external stainless steel probe with 1 meter Teflon cable.

    8. The temperature measuring Range is from -100°C to 40°C or -148° to 104°F.

    9. Temperature Accuracy from -100°C to -80°C  is +/-1.0°C (-148°F to -112°F   +/- 1.8°F).

    10. Temperature Accuracy from -79°C to -10°C   +/- 0.7°C (-111°F to 14°F   +/- 1.3°F).

    11. Temperature Accuracy from -9°C to 40°C   +/- 0.6°C (15°F to 104°F   +/- 1.0°F).

    12. Temperature Accuracy from -148°F to -112°F is  +/- 1.8°F.

    13. Temperature Accuracy from -111°F to 14°F is  +/- 1.3°F.

    14. Temperature Accuracy from 15°F to 104°F is  +/- 1.0°F.

    15. The reading Resolution is 0.1°C or 0.1°F.

    16. Sensor Response Time is T90 of 5 minutes.

    17. LCD Operating Range is from -20°C to 70°C or from -4°F to 158°F. Hence the data logger has to be preferably kept outside the box containing the dry ice.

    18. There are two alarm Thresholds, one each for high and low levels.

    19. This Multi-use Escort iMiniplus Dry ice data logger has a bookmark feature for marking any events by the customer.

    20. This unit is programmable by the customer. We can supply in preprogrammed condition as well if the details are given in advance.

    21. The starting is by push button or timer or both.

    22. If the customer requires it, there is a delay program option. In this case, the recording will start only after a delay period.

    23. Stopping this dry ice temperature recorder is by the stop button. The user can disable this button so that no one will stop by mistake.

    24. The size of this Multi-use, Escort iMiniplus dry ice temperature data recorder is 83x57x17mm, excluding the lug & external sensor.

    25. The weight of this dry ice temperature recorder is 70 grams, including the battery.

    26. The case is made of Polycarbonate/ABS.

    27. The battery is a 3.0 Volt, coin-type user-replaceable lithium battery.

    28. The ingress protection of this Multi-use, dry ice data recorder is IP 64 with the battery cap on.

    29. Warranty is 2 years excluding battery, only for Multiuse data logger.

    30. We can provide NIST traceable calibration report upon specific request, at extra time & charges.

    31. We provide an accuracy Certificate along with every data logger.

    32. Battery Life is 1 to 2 years depending on the usage, temperature conditions etc.

    33. It has a USB to serial connection for connecting to a computer for downloading the data.

    34. The dry ice data logger operates with Console Pro Software.

    35. You can export the data in TXT, CSV, SYLK & LCF formats.

    36. The multi-use model has a re-arm function which enables the user to simply make the logger once again with earlier program details.

    37. It has a protection feature with a password using the Console Pro Software.

    38. Programming and downloading the data is using Console Pro Software.
    FAQ on Dry ice and Dry Ice temperature recorder
    1. What is dry ice? Dry ice is solidified Carbon Dioxide (CO2). The temperature of dry ice is around

      -78.5°C. In order to prepare dry ice, Carbon Dioxide gas is pressurized and cooled down until it becomes liquid. Then pressure is lowered. In this process, the liquid becomes solid ice pieces.

    2. How long will dry ice remain in solid form? It will retain its solid form from 12 to 24 hours based on the surrounding environment.

    3. What are the applications of dry ice? The temperature of dry ice is -78.5°C. Hence we can use it for faster cooling than ice from water. The dry ice is placed inside boxes for transportation of medicines, vaccines, clinical samples, frozen food etc.

    4. How to record the temperature of dry ice during transportation? In order to measure and record the temperature of dry ice during transportation, you may use dry ice data loggers. These come with an external sensor attached to a temperature recorder. You have to keep the recorder out of the box after inserting the sensor into the box.

    This is a preview of the recently viewed products by the user.