Ozone Meter for Climate Measurements
Description for ERP: Ozone meter, model no.VAC-OZ-ONE.
Ozone measuring range: 0 - 1 ppm and 0 - 1.996 µg/m 3
Temperature measuring range: 0 - 50℃.
Relative humidity measuring range: 0 – 99.99%
Battery: 4 x 1.5 V, AAA
VSKU:
Ozone meter for climate measurements
The OZ-ONE ozone meter is used for ozone level concentrations and climate measurements. This device is well applicant at places where the ozone generators were used for odour neutralization or disinfection. It allows monitoring the limit of ozone. The portable device also displays air temperature and humidity values along with calculated dew point and wet bulb temperatures. The measuring device has internal batteries of 4 x 1.5 V, AAA. With single-handed operation and precise and accurate values, the device is adopted for technical as well as commercial monitoring.
Applications
The device is used for mobile ozone measurements.
It is used for quick ozone concentration measurements.
The device is used for climate measurements.
The device is used for long term recording of ozone level concentrations.
The device is used for determining air temperature.
It is used for humidity measurements.
It is used in workplace measurements in industries.
The device is used for environmental analyses.
It is used for examination of production environments.
The device is used for limit monitoring after using ozone generators for odour neutralization or disinfectant.
It is used for car- valeting.
It is used for detecting the ozone levels in hospitals.
It is used for detecting ozone leaks.
The device is used for detecting outdoor ozone pollution.
It is used for monitoring the disinfected hotel rooms.
Features
The device has features for displaying the time-weighted average.
It displays both maximum and minimum measured values.
It has a hold function.
It has an LCD monochromic illuminated display.
The housing design is plastic.
It has a ¼ inch tripod thread.
It has offset adjustment for air temperature and humidity.
It has features for calculating wet bulbs and dew point temperatures.
It has an atmospheric pressure offset feature.
The device has features for measuring the low concentration of ozone.
The device indicates the measured ozone values in ppm or µg/m 3 .
The device has a USB port.
The device includes a calibration certificate.
It has features for automatic switching off of the device when not in use.
The device is featured with push buttons for device controlling.
Specifications
Ozone is measured for a range of 0 to 1 ppm with an accuracy of 0.1 ppm: ± 0.02 ppm or ± 10 % of the current measured value.
Ozone is also measured from a range of 0 to 1.996 µg/m 3 (at 20 °C and 1.013 hPa) with an accuracy of 200 µg/m³: ± 40 µg/m³ or ± 10 % of the current measured value.
Air temperature is measured for a range of 0 to 50℃ with a resolution of 0.1 and an accuracy of 0.6℃.
The relative humidity is measured for a range of 0 to 99.99%.
The power supplied to the ozone meter is from 4 x 1.5 V, AAA internal batteries or by connection to the power bank from the USB port.
The device must have internal sensors for detecting and measuring air temperature (℃ & F), relative humidity and ozone (ppm).
The time-weighted average is for 8 hours.
The short term exposure limit is measured for 15 mins.
The package must consist of measuring device, batteries, transport bag, calibration certificate and an operating manual.
We supply these ozone meters used for air quality control in the USA, UK, Germany, France, Netherlands, Spain, Switzerland, Sweden, and other European countries. Also, we supply these ozone meters used for air quality monitoring in the Middle East and other Asian countries including India, Pakistan, Afghanistan, Bangladesh, Singapore, etc.
Our African offices supply these ozone meters used for climate measurements across all African countries covering South Africa, Kenya, Nigeria, Tanzania, Rwanda, Djibouti, Morocco, Ghana, Ethiopia, Uganda, Morocco, Tunisia, Cameroon, Mauritius, Gabon, Seychelles, etc.
Our Middle East offices supply these ozone meters used for ozone concentration measurement in the United Arab Emirates, Kingdom of Saudi Arabia, Qatar, Oman, Kuwait, Egypt, Lebanon, Bahrain, Libya, Iraq, Erbil, Jordan, etc.
Once the user has seen at least one product this snippet will be visible.
Recently viewed Products
To install this Web App in your iPhone/iPad press and then Add to Home Screen.