True

Product Image

Testo 300 Longlife - Flue gas analyzer

1,578.85 USD 1,578.85 USD 1578.8500000000001 USD

5,523.00 AED

Testo 300 Longlife - Flue gas analyzer

Flue gas analyzer (O2, CO H2-compensated up to 8,000 ppm, NO -
can be retrofitted), model no [VAC 300]
Operating temperature: -5 to +45 °C
Operating humidity: 15 to 90 %RH non-condensing
Memory: 1,000,000 measuring values
Storage battery type: Lithium-ion battery

Days
Hours
Mins
Secs
1

VSKU: 1010000143

1,578.85 USD 1,578.85 USD 1578.8500000000001 USD

5,523.00 AED

    This combination does not exist.


    Add to Cart Buy Now

    Category:

  • Gas Detector

  • Flue gas analyzer to measure O2, CO H2 & NO concentrations

    Longlife - Flue gas analyzer (O2, CO H2-compensated up to 8,000 ppm, NO - can be retrofitted) is integrated with temperature, pressure and gas sensors to measure temperature, have flow pressure and detect CO H2, O2 and NO concentrations. The device has a differential temperature measurement function and is ideal for monitoring heating systems. The gas analyzer can detect up to a value of 8000 ppm. It is provided with a display interface similar to smartphones. The report is generated and emailed to the recipient on site. The device can measure NO concentrations with NO retrofitting.

    Applications

    1. The flue gas analyzer is ideal to monitor and measure heating systems.

    2. It can measure flue gas, draught and flue gas pressure,

    3. It can measure ambient CO and differential temperature.

    4. It can measure gas flow pressure.

    5. Gas pipes are tested with the device.

    6. The device facilitates differential temperature measurement (flow and return temperature on heating systems).

    7. It can measure ambient CO concentrations.

    8. It measures flue and draught on heating systems.

    Features

    1. The flue gas analyzer has fast-response.

    2. The Smart-Touch display assures easy operation identical to a smartphone.

    3. The O2 and CO H2 sensor can measure up to 8,000 ppm.

    4. It has a large 5-inch HD display.

    5. All system measurements can be observed in a glance.

    6. The report documentation is created and can be emailed directly.

    7. The automatic sensor protection ensures a longer sensor life.

    8. Versatile probes are provided permitting fast probe changes.

    9. The additional probes and accessories for measuring gas flow pressure measurement, gas pipe testing, differential temperature measurement and ambient CO measurement are optional with the device package.

    10. The PDF reports directly stored in the instrument are always readily available.

    11. The device has a significant function which enables the customer to sign the reports directly on the instrument.

    12. The reports are directly sent to the office email via WLAN.

    13. The interface function assists direct data transfer of measurement reports to industry/customer-specific software.

    14. It is ready to use straight away.

    15. Integrated Bluetooth® interface is provided.

    16. With the aid of an appropriate printer, an immediate printout of measured values is obtained.

    17. The sensors for O2 and CO have high quality, thus minimum one sensor replacement is saved in the course of a normal working life even when used intensively.

    18. The NO sensor can be retrofitted.

    19. It has a 10-hour rechargeable battery life duration.

    20. Extra-strong magnets are used for easy fixing during the measuring process

    21. 4 strong rubber coated magnets are used for material friendly mounting.

    Specifications

    1. The measuring range of TC Type K (NiCr-Ni)-temperature is from -40 to +1200 °C with ±0.5 °C (0.0 to +100.0 °C), ±0.5 % of mv (Remaining Range) accuracy.

    2. The TC Type K (NiCr-Ni)-temperature resolution is 0.1 °C (-40 to +999.9 °C), 1 °C (Remaining Range)

    3. It has a dimension of 244 (including probe connection) x 98 x 59mm.

    4. Its operating temperature is -5 to 45 °C.

    5. The charging temperature varies from 0 to +45 °C.

    6. It weighs 800g approximately.

    7. It is powered by a lithium-ion battery and a 10hr. duration.

    8. It can store 1,000,000 values and has IP40 protection.

    9. The authorisation abides by 1st German Federal Immission Control Ordinance (BImSchV) EN 50379, Parts 1-3.

    10. The Operating humidity range is 0 to 90 %RH non-condensing.

    11. The flue gas O2 has a 0.1 Vol.% resolution with a measuring range of 0 to 21 Vol.% and an accuracy of ±0.2 Vol.%.

    12. The ambient CO measuring range is 0 to 2000 ppm with an accuracy of ±10 ppm (0 to 100 ppm), ±10 % of mv (101 to 2000 ppm) and 1ppm resolution.

    13. The measuring range of flue gas loss is 0 to 99.9 % and has a 0.1 % resolution.

    14. The differential pressure has a piezoresistive measuring range of -100 to +200 hPa.

    15. . The piezoresistive accuracy of differential pressure is ±0.5 hPa (0 to +50.0 hPa); ±1 % of mv (+50.1 to +100.0 hPa); ±1.5 % of mv (+100.1 to +200 hPa) and 0.01 hPa. resolution.

    16. The Piezoresistive Differential Pressure flue gas Draught has a measuring range -9.99 to +40 hPa., ±0.005 hPa (+0 to +0.1 hPa); ±0.02 hPa (+0.1 to +3.00 hPa); ±1.5 % of mv (3.01 to +40 hPa) accuracy and 0.001 hPa (0 to 0.1 hPa), 0.01 hPa (Remaining Range) resolution.

    17. The calculated Flue gas degree of effectiveness has a measuring range of 0 to 120 % and 0.1 % resolution.

    18. The calculated Flue gas CO₂ (calculated from O₂) has a measuring range of 0 to maximum CO₂, ±0.2 Vol.% accuracy and 0.1 Vol.% resolution.

    19. The Flue gas CO (without H₂-compensation) has a measuring range of 0 to 8000, ±10 ppm or ±10 % of mv (0 to 200 ppm) ±20 ppm or ±5 % of mv (201 to 2000 ppm) ±10 % of mv (2001 to 8000 ppm) accuracy and 1 ppm resolution.

    20. The Piezoresistive differential pressure 4 Pa measurement has -50 to +50 Pa measuring range, ±0.3 Pa (< 10 Pa); ±3 % of mv (Remaining Range) accuracy and 0.1 Pa resolution.

    21. The Flue gas NO has 0 to 3000 ppm measuring range, ±5 ppm (0 to 100 ppm); ±5 % of mv (101 to 2000 ppm); ±10 % of mv (2001 to 3000 ppm) accuracy and 1 ppm resolution.

    We supply this Longlife - Flue gas analyzer (O2, CO H2-compensated up to 8,000 ppm, NO - can be retrofitted) for measuring flue and draught on heating systems in the USA, UK, Germany, France, Netherlands, Spain, Switzerland, Sweden and other European countries. Also, we supply these Longlife - Flue gas analyzer (O2, CO H2-compensated up to 8,000 ppm, NO - can be retrofitted) for measuring gas flow pressure in the Middle East and other Asian countries including India, Pakistan, Afghanistan, Bangladesh, Singapore etc.

    Our African offices supply these Longlife - Flue gas analyzer (O2, CO H2-compensated up to 8,000 ppm, NO - can be retrofitted) for measuring ambient CO concentrations across all African countries covering South Africa, Kenya, Nigeria, Tanzania, Rwanda, Djibouti, Morocco, Ghana, Ethiopia, Uganda, Morocco, Tunisia, Cameroon, Mauritius, Gabon, Seychelles etc.

    Our Middle East offices supply these Longlife - Flue gas analyzer (O2, CO H2-compensated up to 8,000 ppm, NO - can be retrofitted) for measuring flue gas, draught and flue gas pressure in the United Arab Emirates, Kingdom of Saudi Arabia, Qatar, Oman, Kuwait, Egypt, Lebanon, Bahrain, Libya, Iraq, Erbil, Jordan etc.

    This is a preview of the recently viewed products by the user.
    Once the user has seen at least one product this snippet will be visible.

    Recently viewed Products

    To install this Web App in your iPhone/iPad press and then Add to Home Screen.